{"platform":"SmartParking Turkiye EV + Dynamic Load Balancing Bridge","architecture":{"localControlLayer":"PLC / Edge Gateway (Modbus TCP/RTU + local MQTT fail-safe loop)","cloudContextLayer":"ASP.NET Core 10 SignalR Hub (/hubs/parking) + OCPP 1.6J/2.0.1 REST","failSafeGuarantee":"While panel AC supply is healthy, Edge PLC enforces autonomous 16A fallback strictly on cloud/CSMS connectivity loss, stale ct-telemetry, or 30s watchdog timeout (full mains outage drops load to 0 A via hardware protection)."},"electricalModel":{"defaultPhases":3,"defaultLineToLineVoltageV":400,"singlePhaseNominalVoltageV":230,"dcConversionEfficiency":0.94,"dcAcPowerFactor":0.98,"acPanelFormula":"P_ac = sqrt(3) * V_ll * I_ac (3-phase 400V) or V_ln * I_ac (1-phase 230V)","dcOutputFormula":"P_dc = V_dc * I_dc (DC bus telemetry reported on voltageV/currentA)","dcToAcPanelCurrentFormula":"I_ac = P_dc * 1000 / (sqrt(3) * V_ll * efficiency * powerFactor) with efficiency=0.94, PF=0.98 so DLB panel CT headroom never underestimates AC draw","singlePhaseDcToAcPanelCurrentFormula":"I_ac = P_dc * 1000 / (V_ln * efficiency * powerFactor) for 1-phase 230V","apparentVsRealPowerNote":"sqrt(3) * V_ll * I_ac yields apparent power S (kVA) -> acGridInputApparentPowerKva; real panel power P = S * PF -> acGridInputRealPowerKw; closed-loop check P_dc / P_real = 0.94 -> measuredConversionEfficiency","ocppRateUnitAmperesScope":"OCPP SetChargingProfile limits (rateUnit A) are AC panel-side per-phase amperes; DC chargers convert A <-> kW through eta and PF in both directions","perChargerTelemetryFields":["dcOutputPowerKw","acGridInputCurrentA","acGridInputApparentPowerKva","acGridInputRealPowerKw","measuredConversionEfficiency"],"examples":"22 kW AC 3-phase = 31.8 A/phase; 94.5 kW DC @ 400V AC input (eta=0.94, PF=0.98) = 148.1 A/phase -> S = 102.61 kVA, P = 100.56 kW; 142 kW DC = 222.5 A/phase -> S = 154.15 kVA, P = 151.07 kW; override via phases=1 for 230V 1-phase","enforcementUnit":"A"},"ocppCompatibility":{"standard":"OCPP 1.6J / 2.0.1 SetChargingProfile","customChargerFirmwareRequired":false,"supportedPurposes":["TxDefaultProfile","TxProfile","ChargePointMaxProfile"],"note":"Upstream Edge CT/PLC feeds panel headroom to cloud/OCPP CSMS; stock OCPP chargers receive standard SetChargingProfile frames without internal firmware changes."},"fallbackPolicy":{"defaultFallbackTimeoutSeconds":30,"defaultFallbackLimitAmperes":16,"appliesOnlyWhilePanelPowerHealthy":true,"triggerConditions":["cloud_or_csms_connectivity_loss","stale_or_missing_ct_telemetry","heartbeat_watchdog_timeout"],"fullPowerOutageBehavior":"Full mains/grid power outage drops charger supply to 0 A via physical protection; the 30s / 16A watchdog fallback applies strictly to comms/telemetry degradation while AC power is healthy."},"controlPrecedence":[{"priority":1,"layer":"Local Physical Breaker / Protection Relay / E-Stop","transport":"Hardwired","authority":"Absolute hardware safety; cannot be overridden by any software or network command."},{"priority":2,"layer":"Local Edge PLC / Modbus CT Meter Loop","transport":"Modbus TCP/RTU","authority":"Enforces real-time subpanel headroom clamp and 30s / 16A comms-loss watchdog; caps any higher cloud setpoint."},{"priority":3,"layer":"MQTT Setpoint & OCPP SetChargingProfile","transport":"MQTT (smartparking/dlb/{siteId}/panel/{panelId}/set-limit) / OCPP 1.6J-2.0.1","authority":"Dynamic operational setpoints (ChargePointMaxProfile > TxProfile > TxDefaultProfile via stackLevel), bounded by Priority 2."},{"priority":4,"layer":"SignalR Hub & Cloud REST Views","transport":"SignalR (/hubs/parking) / HTTPS REST","authority":"Cloud context, monitoring, and telemetry broadcast (read-only observer; never overrides local PLC safety clamps)."}],"signalREvents":[{"eventName":"OnSlotStatusChanged","fields":["parkingLotId","slotCode","isOccupied","plateNumber","timestamp"]},{"eventName":"OnChargingProfileApplied","fields":["chargerId","phases","limitKw","limitAmperes","purpose","fallbackTimeoutSeconds","timestampUtc"]},{"eventName":"OnDlbTelemetryProcessed","fields":["siteId","panelId","phases","rateUnit","availableEvseBudgetAmperes","totalAllocatedAmperes","fallbackTimeoutSeconds","timestampUtc"]}],"mqttTopics":{"dlbCommand":"smartparking/dlb/{siteId}/panel/{panelId}/set-limit","meterTelemetry":"smartparking/dlb/{siteId}/panel/{panelId}/ct-telemetry"},"ocppEndpoints":{"chargers":"/api/v1/ocpp/chargers","setChargingProfile":"/api/v1/ocpp/chargers/{id}/charging-profile","subpanelAllocation":"/api/v1/ocpp/dlb/subpanel-allocation","ctTelemetryIngest":"/api/v1/ocpp/dlb/ct-telemetry","ctTelemetryHistory":"/api/v1/ocpp/dlb/telemetry-history"}}